- SOM
- Departments and Offices
- SOM Departments
- Pathology
- UMMC Lab Services
- Lab Test List
- Laboratory
- Tests
Tests
Main Content
Human Immunodeficiency Virus RT-PCR, Quantitative (Viral Load)
Test Name: | Human Immunodeficiency Virus RT-PCR, Quantitative (Viral Load) | ||
Epic Order Code: | LAB919 | ||
CPT Code: | 57536 | ||
Specimen(s) Type: | Plasma | ||
Acceptable Container(s): | 2 X Top is purple (lavender). | ||
Testing Schedule: | Tests performed in 20 sample minimum batches. Call lab at (601) 984-2365 for availability. | ||
Turn Around Time: | STAT: NA | ||
Routine: 8 hours after the run is started. | |||
Collection Information: | No special patient preparation is required. Obtain specimen by standard collection procedures. Two (2) tubes of blood are required. | ||
Transport Information: | Deliver to lab immediately. All specimens must be signed into the laboratory. | ||
Reference Client: | If unable to deliver to lab immediately, centrifuge the specimen and separate the plasma from the red cells within 24 hours. Store and transport the specimen at 2-8° C within 6 days. If longer periods of storage are required the specimen must be frozen at -20° C. | ||
Causes for Rejection: | Improperly labeled, incorrect container, contaminated, insufficient quantity, incorrect/delay in transport. | ||
Reference Range: | No normal range. Assay determines increase and decrease of viral load. | ||
Additional Information: | This test monitors progression of HIV and response to antiviral agents. |